Rev. 12/93
9.5 SCANNER HEIGHT ADJUSTMENT
When:
Purpose:
How:
1. Remove the upper right cover [A]. (Refer to the upper right cover
removal.)
2. Remove the lens unit cover [B].
3. Move the third scanner to the far right position.
A095/A096/A097
If optically skewed images appear after
adjusting the 1st and 2nd scanner positions.
To maintain a proper copy image.
Turn the 3rd scanner height adjusting cam.
This changes the 3rd scanner's height.
5-126
[A]
[B]
FSM