BULLETIN NUMBER:
APPLICABLE MODEL: FT6645/6655
SUBJECT: SCANNER FLAT CABLE, LENS COVER INSTALLATION
SYMPTOM:
Rubbing noise from lens unit during scanning.
CAUSE:
The scanner flat cable and the lens unit cover are installed too close to each other.
SOLUTION:
1. Loosen the two screws [C] fixing the lens unit cover.
2. Pull the lens unit cover [A] to the front.
3. Tighten the two screws [C].
4. Loosen the screw [D] fixing the scanner flat cable.
5. Turn the scanner flat cable [B] counterclockwise (it can only rotate slightly).
6. Tighten the screw [D].
[B]
6645/6655-013
[A]
[C]
[D]
[B]
04/15/94
[A]