[A]
[A]
[C]
[B]
[D]
[E]
4. Remove five plastic caps [A] on the copier's left cover.
5. Install the front connecting bracket [B] (2 screws - M4 x 12) and the rear
connecting bracket [C] (2 screws - M4 x 12) on the copier.
6. Stick the entrance guide mylar [D] on the copier exit area as shown.
NOTE: Align the edge [E] of the cover and the mylar.
FSM
8-9
A095/A096/A097