1. SERVICE REMARKS

1.1 HANDLING THE DRUM

The organic photoconductor drum is comparatively more sensitive to light
and ammonia gas than a selenium drum.
1. Never expose the drum to direct sunlight.
2. Never touch the drum surface with bare hands. When the drum surface
is touched with fingers or becomes dirty, wipe with a dry cloth or clean
with wet cotton. Wipe with a dry cloth after cleaning with wet cotton.
3. Never use alcohol to clean the drum; alcohol dissolves the drum surface.
4. Store the drum in a cool, dry place away from heat.
5. Take care not to scratch the drum as the drum layer is thin and is easily
damaged.
6. Never expose the drum to corrosive gases such as ammonia gas.
7. Always keep the drum in its protective sheet when out of the copier. Also
always close the protective shutter on the drum unit when keeping the
drum unit out of the copier. Doing so avoids exposing the drum to bright
light or direct sunlight. This will protect the drum from light fatigue.
8. Process control data initial setting (
be performed when a new drum is installed.
FSM
SP Adjustment: PAGE 1) must
1
4-1