Development; Process Sensor - Ricoh A095 Service Manual

Gestetner ricoh savin
Table of Contents

Advertisement

Rev. 10/94

1.7 DEVELOPMENT

SC341 - Development motor locked
Definition: [level: D]
Development motor OL (overload) signal stays low more than 1 second in
development motor on condition.
Possible causes:
Extra load in the development unit
Development motor defective
Main control board defective
SC342 - Toner collection motor locked
Definition: [level: D]
The toner collection sensor output does not change (OFF → ON or ON →
OFF) for more than 2.55 seconds in the toner collection motor on condition.
Possible causes:
Toner collection sensor defective
Toner collection motor defective
Toner clog in the toner collection pipe
SC343 - Toner collection bottle at improper position
Definition: [level: D]
Toner bottle set switch is off and the front door is closed.
Possible causes:
Toner collection bottle set switch defective
Toner collection bottle is set incorrectly

1.8 PROCESS SENSOR

SC351 - Abnormal Vsg Detection (Vsg > 4.2V)
Definition: [level: C]
The detected Vsg value is over 4.2 V.
Possible causes:
ID sensor defective
Main control board defective
A095/A096/A097