6.9.2 Two Sided Original Mode

[A]
[C]
1. Remove the copier's left scale [A] (2 screws).
2. Remove the small cover at the rear side on the upper DJF cover then
turn on DIP SW 101-2, 101-4 and 102-1.
3. Set a sheet of A4 / 8
paper on the original table.
4. Push SW 101 [B].
5. After the original stops on the exposure glass, gently raise the DJF so
that the original does not move.
6. Confirm that the gap between the trailing edge of the paper and the left
edge [C] of the original rear scale is 10 ± 2 mm.
7. It the gap is not within specification, adjust the registration by using the
copier SP mode (
NOTE: 1. Before setting the original on the original table again, open
and close the feed unit cover [C].
2. After completing the adjustment, return the DIP switches to
their original condition.
8. If the registration cannot be adjusted within specifications even though
the SP data is changed to the maximum value, return the data to "00".
9. Adjust the vertical adjustment by turning VR102 on the DJF main board.
FSM
10 ± 2 mm
" x 11" (53 ~ 80 g/m
1/2
SP Adjustment - PAGE 6).
1
7-29
Rev. 4/15/94
VR102
/ 14 ~ 22 lb) sideways