Tech Service Bulletin No. A095/A096/A097– 006
Page 2 of 2
NOTE:
Since the ID Sensor pattern becomes lighter due to lubrication, the toner concentration in the
Developer becomes much higher, causing toner scattering or dirty background.
The parts listed below are PM parts, therefore they should be replaced every 120K copies. Both parts are
included in the Lower Drum Unit. Please follow the procedure listed below when replacing the Lubricant Bar.
The replacement procedure for the lubricant bar is as follows.
1. Remove the Cleaning Release lever [A] (1 screw).
2. Remove the Spring [B].
3. Remove the Cam Gear-35Z [C] (1 E-ring, Spacer M-6).
4. Remove the Cleaning Brush Bushing [D] (1 screw).
5. Remove the Cleaning Blade Bracket Ass'y [E].
6. Remove the Lubricant Bar Ass'y [F] (3 screws).
7. Remove the Lubricant Bar Seal [G] (3 screws) and replace it.
8. Remove the Stopper [H] and replace the Lubricant Bar [I].
[B]
[C]
[D]
NEW PART NUMBER
A1763515
A1763522
A1763518
[E]
[F]
[G]
DESCRIPTION
Lubricant Bar
Lubricant Bar Seal
Stopper
[A]
[H]
[I]
REFERENCE
QTY
PAGE
ITEM
1
61
59
1
61
60
1
61
61