4.2 QUENCHING LAMP REPLACEMENT
1. Remove the OPC drum. (Refer to Drum Unit Removal and OPC Drum
Replacement.)
NOTE: Wrap a protective sheet or a few sheets of paper around the
drum to protect it from light.
2. Slightly pull up the wires [A] on the quenching lamp, then insert the head
of the small flat head screw driver [B] between the quenching lamp and
the drum unit casing to release the hook [C] at the center of the
quenching lamp.
NOTE: Do not pull the wire too strongly.
3. Disconnect the connector [D].
4. Replace the quenching lamp.
⇒
5. Turn on the main switch, then perform process control initial setting
(
SP Adjustment – PAGE.1).
1
FSM
[A]
[B]
[D]
CN663
5-49
Rev. 8/29/97
[C]
A095/A096/A097