Tech Service Bulletin No. 6645/6655/6665 - 057
Page 2 of 5
• •
ANTI-CONDENSATION HEATER CONNECTORS
To meet very strict power consumption specifications in Auto "OFF" mode, the anti-condensation heater
connectors are kept disconnected at the factory. At the time of installation, check the humidity conditions at
the customer site and connect the heater connectors if necessary.
CAUTION:
Unplug the copier power cord before setting the anti-condensation heater connectors.
This is because even though the main switch may be turned "OFF", AC current is still
supplied to the anti-condensation circuit.
• •
INSTRUCTION SHEET
An additional explanation sheet has been added to the Operating Instructions. Please make copies of
pages 3, 4 and 5 of this bulletin and add them to the Operating Instructions for all Energy Star Compliant
FT6645/6655/6665 copiers.