Ricoh A095 Service Manual page 283

Gestetner ricoh savin
Table of Contents

Advertisement

[C]
[A]
4. Turn the screw [A] to correct the position of the filament. The left edge of
the exposure lamp [B] should be directly beneath the center of the sight
hole [C] in the reflector cover.
CAUTION: Do not touch the screw [D].
5. Turn on the main switch and enter SP mode, then perform the process
control data initial setting (
A095/A096/A097
[B]
SP Adjustment – PAGE 1).
1
5-124
[B]
[C]
[A]
[D]
FSM

Advertisement

Table of Contents
loading

This manual is also suitable for:

A096A097

Table of Contents