Optics; Exposure Glass Removal - Ricoh A095 Service Manual

Gestetner ricoh savin
Table of Contents

Advertisement

Rev. 4/15/94

2. OPTICS

2.1 EXPOSURE GLASS REMOVAL

1. Turn off the main switch.
2. Remove the left scale [A] (2 shoulder screws).
3. Remove the rear scale [B] (3 screws).
4. Grasp the left edge of the exposure glass [C] and lift slightly. Slide the
other edge out from under the right glass holder [D]. Remove the
exposure glass.
NOTE: When reinstalling the exposure glass, make sure that the mark
(white: A096 copier/red: A095 copier) on the edge of the glass is
located at the rear right corner. This side is smoother and it
generates less static electricity when the RDH is used.
A095/A096/A097
[A]
[C]
5-10
[B]
[D]