8. Fusing unit
(every 120 K)
Replace stripper
pawls, hot roller,
pressure roller, and
pressure roller
bearings. Lubricate
the isolating busing.
(every 240 K)
9. Exit unit
(every 80 K)
Replace the
ozone filter
(every 360 K)
10. Rear side
(every 80 K)
Replace the drum
grounding plate
(every 360 K)
11. Exterior
(every 80 K)
12. Copy Quality
CAUTION: Perform the developer initial setting only when new
developer is installed.
Never make any copies before the developer initial setting.
A095/A096/A097
8-1. Clean the entrance and exit guide plates.
8-2. Clean the thermistor film and apply Silicone
oil.
8-3. Clean the stripper pawls.
8-4. Replace the oil supply roller.
8-5. Replace the oil supply roller cleaning roller. (A097
only)
8-6. Replace the pressure roller cleaning roller.
9-1. Clean the exit rollers.
9-2. Inspect the antistatic brush.
9-3. Clean the exit sensor.
10-1. Lubricate the gears.
10-2. Inspect the timing belts.
11-1. Clean the covers.
12-1. Perform the developer initial setting.
(