Resetting The System Attention Led - IBM TotalStorage NAS Gateway 500 Service Manual

Hide thumbs Also See for TotalStorage NAS Gateway 500:
Table of Contents

Advertisement

Note: This will not reset the system attention LED.
3. If the system error log indicates service support is required, or there are entries in the service
processor error log, see "Entry MAP" on page 39 with the information noted from the error log.

Resetting the system attention LED

As a user with root authority, type diag on the command line, and do the following:
1. Select Task Selection.
2. On the Task Selection Menu, select Identify and Attention Indicators.
3. When the list of LEDs is displayed, use the cursor to highlight Set System Attention Indicator to
Normal.
4. Press Enter, and then press F7 to commit. This action turns off the LED.
If the system is powered off, access the service processor menus. From the service processor main menu,
do the following:
1. Select System Information Menu.
2. Select LED Control Menu.
3. Select Clear System Attention Indicator. This action turns off the LED.
Chapter 2. Problem determination overview
37