IBM TotalStorage NAS Gateway 500 Service Manual page 182

Hide thumbs Also See for TotalStorage NAS Gateway 500:
Table of Contents

Advertisement

Table 16. Service processor error codes (continued)
Error code Description
4066 0013 DIMM fault
4066 0014 DIMM fault
4066 0015 DIMM fault
4066 0016 DIMM fault
4066 0017 DIMM fault
4066 0018 DIMM fault
4066 0019 DIMM fault
4066 001A DIMM fault
4066 001B DIMM fault
4066 001C DIMM fault
4066 001D DIMM fault
4066 001E DIMM fault
4066 001F DIMM fault
4066 00B0 Bus controller failure
4066 00B1 Bus controller failure
4066 00B3 Processor/VPD problem detected
4066 00B4 Processor/VPD problem detected
4066 00B7 Insufficient hardware resources were detected to
continue IPL of the system after processor
subsystem testing and initialization was
completed.
4066 00D1 Informational message
4066 0100 Memory extender 0 on processor card 1
162
NAS Gateway 500 Service Guide
Action or
possible failing FRU
DIMM
Location code: U0.1-P1-C1-M3
DIMM
Location code: U0.1-P1-C1-M7
DIMM
Location code: U0.1-P1-C1-M5
DIMM
Location code: U0.1-P1-C1-M2
DIMM
Location code: U0.1-P1-C1-M4
DIMM
Location code: U0.1-P1-C2-M8
DIMM
Location code: U0.1-P1-C2-M6
DIMM
Location code: U0.1-P1-C2-M1
DIMM
Location code: U0.1-P1-C2-M3
DIMM
Location code: U0.1-P1-C2-M7
DIMM
Location code: U0.1-P1-C2-M5
DIMM
Location code: U0.1-P1-C2-M2
DIMM
Location code: U0.1-P1-C2-M4
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
1. Check for system firmware updates.
2. Processor card 1
Location code: U0.1-P1-C1
1. Check for system firmware updates.
2. Processor card 2
Location code: U0.1-P1-C2
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Informational message
Processor card,
Location code: U0.1-P1-C1

Advertisement

Table of Contents
loading