IBM TotalStorage NAS Gateway 500 Service Manual page 190

Hide thumbs Also See for TotalStorage NAS Gateway 500:
Table of Contents

Advertisement

Table 16. Service processor error codes (continued)
Error code Description
4068 001F DIMM fault
4068 00B0 Bus controller failure
4068 00B1 Bus controller failure
4068 00B3 Processor/VPD problem detected
4068 00B4 Processor/VPD problem detected
4068 00B7 Insufficient hardware resources were detected to
continue IPL of the system after processor
subsystem testing and initialization was
completed.
4068 00D1 Informational message
4068 0100 Memory extender 0 on processor card 1
4068 0101 Memory extender 2 on processor card 1
4068 0130 Memory extender 0 on processor card 2
4068 0131 Memory extender 2 on processor card 2
4068 0A03 Reboot message on VPD channel 3 processor
card 1. Reboot is necessary for run-time array
gard to take effect.
4068 0A04 Reboot message on VPD channel 4 processor
card 2. Reboot is necessary for run-time array
gard to take effect.
4068 0B00 Problem with internal RIO interface (I/O slot 0,
I/O port 0)
4068 0B01 Problem with internal RIO interface (I/O slot 0,
I/O port 1)
4068 0B02 Problem with internal RIO interface (I/O slot 0,
I/O port 2)
170
NAS Gateway 500 Service Guide
Action or
possible failing FRU
DIMM
Location code: U0.1-P1-C2-M4
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
1. Check for system firmware updates.
2. Processor card 1
Location code: U0.1-P1-C1
1. Check for system firmware updates.
2. Processor card 2
Location code: U0.1-P1-C2
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Informational message
Processor card,
Location code: U0.1-P1-C1
Processor card,
Location code: U0.1-P1-C1
Processor card,
Location code: U0.1-P1-C2
Processor card,
Location code: U0.1-P1-C2
Reboot the system in slow mode. Run
diagnostics, and then go to "MAP 0235: System
Array Self-Repair Problem Resolution" in the
RS/6000 Eserver pSeries Diagnostic
Information for Multiple Bus Systems.
Reboot the system in slow mode. Run
diagnostics, then go to "MAP 0235: System
Array Self-Repair Problem Resolution" in the
RS/6000 Eserver pSeries Diagnostic
Information for Multiple Bus Systems.
CEC backplane, U0.1-P1.
CEC backplane, U0.1-P1.
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1
4. Call service support.

Advertisement

Table of Contents
loading

Table of Contents