Table 15. Firmware error codes (continued)
Error code Description
2602 0001 Description: Invalid PCI adapter vendor ID
Action:
Attention:
administrator that the slot that the adapter is being moved to is available to the partition in which
the adapter presently resides.
1. Move adapter to another slot (behind a different PCI bus).
2. Check for available firmware updates for adapter. Apply update if available.
3. Run diagnostics on the adapter. Replace if indicated.
4. Replace adapter.
5. Check for system firmware updates. Apply update if available.
6. If the card is in the system drawer, replace the PCI riser card, location: U0.1-P2. If the card is
in an I/O subsystem, replace the I/O backplane that contains the slot in which the adapter was
originally installed, location: U0.dd-P1.
2602 0002 Description: Invalid PCI adapter device ID
Action:
Attention:
administrator that the slot that the adapter is being moved to is available to the partition in which
the adapter presently resides.
1. Move adapter to another slot (behind a different PCI bus).
2. Check for available firmware updates for adapter. Apply update if available.
3. Run diagnostics on the adapter. Replace if indicated.
4. Replace adapter.
5. Check for system firmware updates. Apply update if available.
6. If the card is in the system drawer, replace the PCI riser card, location: U0.1-P2. If the card is
in an I/O subsystem, replace the I/O backplane that contains the slot in which the adapter was
originally installed, location: U0.dd-P1.
2602 0007 Description: PCI device I/O or memory space request could not be satisfied
Action:
1. If the location code identifies a slot:
a. Reseat the adapter and reboot the system.
b. Replace the adapter.
c. Check for system firmware update. Apply update if available.
2. If the location code identifies an I/O planar:
a. Check for system firmware updates. Apply update if available.
b. Replace the I/O planar.
3. Call service support.
Before moving the adapter to another slot, verify with the customer or system
Before moving the adapter to another slot, verify with the customer or system
Action or
possible failing FRU