System vital product data (VPD) update procedure

If you replaced the operator panel with a new FRU, perform the following procedure to ensure that the
VPD is correct.
1. After you install the new operator panel, wait for the operator panel to display the OK message.
2. Start the Service Processor Firmware menu.
3. At the command prompt, type the code that accesses the hidden menus. If necessary, call your local
support center to obtain the code.
4. Press Return to continue.
364
NAS Gateway 500 Service Guide
Service Processor Firmware
Firmware Level: xxxxxxxx
Copyright 1999, IBM Corporation
Main Menu
1. Service Processor Setup
2. System Power Control Menu
3. System Information Menu
4. Language Selection
5. Call In/Call Out Setup
6. Set System Name
99. Exit from Menu
1>
Command Prompt
This menu is for IBM Authorized use only. If you
have not been authorized to use this menu, please
discontinue use immediately.
Press Return to continue, or X to return to menu 1.
VPD Serial Number is not programmed.
Enter the VPD Serial Number (7 ASCII digits): xxxxxxx