Table 17. Common firmware error codes (continued)
Error code Description
B10F 1675 Service processor failure
B10F 1681 Service processor firmware update invalid
B10F 1682 Service processor firmware update invalid
B10F 1683 Service processor firmware update invalid
B1xx 0013 A firmware update has failed because the
update image is invalid. The update was stopped
before any changes were made to the currently
installed firmware.
B1xx 4600 Service processor failure
B1xx 4601 System processor failure
B1xx 4602 Service processor firmware failure
B1xx 4603 Service processor firmware corrupted
B1xx 4606 Firmware failure
B1xx 4608 Service processor early termination
B1xx 460A TOD clock has been reset
B1xx 460B TOD battery failure
B1xx 4611 Service processor failure
Action or
possible failing FRU
CEC backplane
Location code: U0.1-P1
Call service support.
Call service support.
Call service support.
Install a valid firmware image for the specific
type and model.
CEC backplane
Location code: U0.1-P1
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
1. Do a slow boot (see "Performing slow boot"
on page 125), and then look at the service
processor error log. Look for the first new
error after the B1xx 4602. Go to the
"Checkpoint and error code index" on
page 127 with the new error code and
perform the action indicated. If there are no
new error codes, go to "MAP 1540: Problem
Isolation Procedures" on page 69.
2. Call service support.
1. Reload system firmware.
2. CEC backplane
Location code: U0.1-P1
1. Check for system firmware updates.
2. Operator panel
Location code: U0.1-L1
3. CEC backplane
Location code: U0.1-P1
1. Reset the system by disconnecting and
reconnecting system power.
2. Reload system firmware.
3. CEC backplane
Location code: U0.1-P1
1. Set TOD clock.
2. CEC backplane
Location code: U0.1-P1
TOD battery
Location code: U0.1-P1-V3
1. Processor card
Location code: U0.1-P1-C1
2. CEC backplane
Location code: U0.1-P1