Table 16. Service processor error codes (continued)
Error code Description
406D 00B4 Processor/VPD problem detected.
406D 00B7 Insufficient hardware resources were detected to
continue IPL of the system after processor
subsystem testing and initialization was
completed.
406D 00D1 Informational message
406D 0100 Memory extender 0 on processor card 1
406D 0101 Memory extender 2 on processor card 1
406D 0130 Memory extender 0 on processor card 2
406D 0131 Memory extender 2 on processor card 2
406D 0A03 Reboot message on VPD channel 3 processor
card 1. Reboot is necessary for run-time array
gard to take effect.
406D 0A04 Reboot message on VPD channel 4 processor
card 2. Reboot is necessary for run-time array
gard to take effect.
406D 0B00 Problem with internal RIO interface (I/O slot 0,
I/O port 0)
406D 0B01 Problem with internal RIO interface (I/O slot 0,
I/O port 1)
406D 0B02 Problem with internal RIO interface (I/O slot 0,
I/O port 2)
406D 0B03 Problem with internal RIO interface (I/O slot 0,
I/O port 3)
406D 0B40 Problem with controller chip on CEC backplane
Action or
possible failing FRU
1. Check for system firmware updates.
2. Processor card 2
Location code: U0.1-P1-C2
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Informational message
Processor card,
Location code: U0.1-P1-C1
Processor card,
Location code: U0.1-P1-C1
Processor card,
Location code: U0.1-P1-C2
Processor card,
Location code: U0.1-P1-C2
Reboot the system in slow mode. Run
diagnostics, and then go to "MAP 0235: System
Array Self-Repair Problem Resolution" in the
RS/6000 Eserver pSeries Diagnostic
Information for Multiple Bus Systems.
Reboot the system in slow mode. Run
diagnostics, then go to "MAP 0235: System
Array Self-Repair Problem Resolution" in the
RS/6000 Eserver pSeries Diagnostic
Information for Multiple Bus Systems.
CEC backplane, U0.1-P1
CEC backplane, U0.1-P1
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1.
4. Call service support.
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1.
4. Call service support.
1. CEC backplane, U0.1-P1.
2. Call service support.