Table 16. Service processor error codes (continued)
Error code Description
4067 0EE5 Firmware error, no callout available
4068 0001 Scan interface basic assurance tests detected a
CEC backplane fault.
4068 0002 CEC backplane fault
4068 0003 Scan interface basic assurance tests detected
processor fault.
4068 0004 Processor fault
4068 000E Processor capacity card
4068 0010 DIMM fault
4068 0011 DIMM fault
4068 0012 DIMM fault
4068 0013 DIMM fault
4068 0014 DIMM fault
4068 0015 DIMM fault
4068 0016 DIMM fault
4068 0017 DIMM fault
4068 0018 DIMM fault
4068 0019 DIMM fault
4068 001A DIMM fault
4068 001B DIMM fault
4068 001C DIMM fault
4068 001D DIMM fault
4068 001E DIMM fault
Action or
possible failing FRU
1. Check for system firmware updates.
2. Call service support.
CEC backplane
Location code: U0.1-P1
1. Check JTAG cable connections
2. CEC backplane
Location code: U0.1-P1
1. Check JTAG cable connections.
2. Processor card
Location code: U0.1-P1-C1
1. Check JTAG cable connections.
2. Processor card
Location code: U0.1-P1-C2
Operator panel
Location code: U0.1-L1
DIMM
Location code: U0.1-P1-C1-M8
DIMM
Location code: U0.1-P1-C1-M6
DIMM
Location code: U0.1-P1-C1-M1
DIMM
Location code: U0.1-P1-C1-M3
DIMM
Location code: U0.1-P1-C1-M7
DIMM
Location code: U0.1-P1-C1-M5
DIMM
Location code: U0.1-P1-C1-M2
DIMM
Location code: U0.1-P1-C1-M4
DIMM
Location code: U0.1-P1-C2-M8
DIMM
Location code: U0.1-P1-C2-M6
DIMM
Location code: U0.1-P1-C2-M1
DIMM
Location code: U0.1-P1-C2-M3
DIMM
Location code: U0.1-P1-C2-M7
DIMM
Location code: U0.1-P1-C2-M5
DIMM
Location code: U0.1-P1-C2-M2