Table 16. Service processor error codes (continued)
Error code Description
406E 0013 DIMM fault
406E 0014 DIMM fault
406E 0015 DIMM fault
406E 0016 DIMM fault
406E 0017 DIMM fault
406E 0018 DIMM fault
406E 0019 DIMM fault
406E 001A DIMM fault
406E 001B DIMM fault
406E 001C DIMM fault
406E 001D DIMM fault
406E 001E DIMM fault
406E 001F DIMM fault
406E 00B0 Bus controller failure
406E 00B1 Bus controller failure
406E 00B3 Processor/VPD problem detected.
406E 00B4 Processor/VPD problem detected.
406E 00B7 Insufficient hardware resources were detected to
continue IPL of the system after processor
subsystem testing and initialization was
completed.
406E 00D1 Informational message
406E 0100 Memory extender 0 on processor card 1
192
NAS Gateway 500 Service Guide
Action or
possible failing FRU
DIMM
Location code: U0.1-P1-C1-M3
DIMM
Location code: U0.1-P1-C1-M7
DIMM
Location code: U0.1-P1-C1-M5
DIMM
Location code: U0.1-P1-C1-M2
DIMM
Location code: U0.1-P1-C1-M4
DIMM
Location code: U0.1-P1-C2-M8
DIMM
Location code: U0.1-P1-C2-M6
DIMM
Location code: U0.1-P1-C2-M1
DIMM
Location code: U0.1-P1-C2-M3
DIMM
Location code: U0.1-P1-C2-M7
DIMM
Location code: U0.1-P1-C2-M5
DIMM
Location code: U0.1-P1-C2-M2
DIMM
Location code: U0.1-P1-C2-M4
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
1. Check for system firmware updates.
2. Processor card 1
Location code: U0.1-P1-C1
1. Check for system firmware updates.
2. Processor card 2
Location code: U0.1-P1-C2
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Informational message
Processor card,
Location code: U0.1-P1-C1