Table 16. Service processor error codes (continued)
Error code Description
4067 0A04 Reboot message on VPD channel 4 processor
card 2. Reboot is necessary for run-time array
gard to take effect.
4067 0B00 Problem with internal RIO interface (I/O slot 0,
I/O port 0)
4067 0B01 Problem with internal RIO interface (I/O slot 0,
I/O port 1)
4067 0B02 Problem with internal RIO interface (I/O slot 0,
I/O port 2)
4067 0B03 Problem with internal RIO interface (I/O slot 0,
I/O port 3)
4067 0B40 Problem with controller chip on CEC backplane
4067 0BF0 Problem with RIO interface (I/O slot 0, I/O port
3)
4067 0C10 Processor 0 configuration error: VPD mismatch
for processor card 0. (Service processor code
problem.)
4067 0C11 Processor 1 configuration error: VPD mismatch
for processor card 1. (Service processor code
problem.)
4067 0CA5 Invalid system configuration
4067 0CA6 No usable memory left in the system. The
system must be rebooted.
4067 0CA9 Incorrect or incompatible DIMMs are installed.
4067 0CAA System memory exceeds the limit for this
system type and model.
Action or
possible failing FRU
Reboot the system in slow mode. Run
diagnostics, then go to "MAP 0235: System
Array Self-Repair Problem Resolution" in the
RS/6000 Eserver pSeries Diagnostic
Information for Multiple Bus Systems.
CEC backplane, U0.1-P1
CEC backplane, U0.1-P1
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1
4. Call service support.
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1
4. Call service support.
1. CEC backplane, U0.1-P1.
2. Call service support.
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1
4. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check that the processor cards and DIMMs
are properly installed and configured.
2. If there are any FRUs listed in the service
processor error log entry, replace them one
at a time.
3. Go to "MAP 1540: Problem Isolation
Procedures" on page 69.
Go to "MAP 1240: Memory Problem Resolution"
on page 52.
Check that the DIMMs are properly configured
and are the right type for the system.
Remove the DIMMs until the memory does not
exceed the limit for this system type and model.
Chapter 5. Error code to FRU index
167