Table 15. Firmware error codes (continued)
Error code Description
20D1 000D Function to get time-of-day failed.
20D1 000E Function to get time-of-day failed.
20D1 000F Hypervisor call to reset PHB or to check for
drawer existence failed.
20D1 0010 Stack underflow from fibre-channel adapter
20D1 0011 PHB recovery was not successful. Open
firmware received failure in phb-recovery-buff.
20D1 0012 Attention:
been disconnected from the system.
20E0 0001 Privileged-access password entry error.
20E0 0004 Battery drained or needs replacement.
20E0 0009 Invalid password entered - system locked.
20EE 0003 IP parameter requires 3 dots "."
20EE 0004 Invalid IP parameter
20EE 0005 Invalid IP parameter (>255)
20EE 0007 Keyboard not found
One of the I/O subsystems has
Action or
possible failing FRU
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
1. Check for microcode updates for the
fibre-channel adapter. Apply an update if
available.
2. Check for system firmware updates. Apply
an update if available.
3. Call service support.
1. Check for system firmware updates. Apply
update if available.
2. Call service support.
This is indicates that an I/O subsystem that was
previously in the configuration was not found
during the current boot.
1. Check for system firmware updates. Apply
the update if available.
2. Call service support.
The password has been entered incorrectly.
Retry installing the password.
1. Replace battery.
Location code: U0.1-P1-V3
2. If problem persists, replace the CEC
backplane
Location code: U0.1-P1
The password has been entered incorrectly
three times.
Turn off, then turn on the system unit, and then
enter the password correctly.
Enter valid IP parameter.
Example: 000.000.000.000
Enter valid IP parameter.
Example: 000.000.000.000
Enter valid IP parameter.
Example: 255.192.002.000
Replace the CEC backplane.
Location code: U0.1-P1