Table 16. Service processor error codes (continued)
Error code Description
406C 001F DIMM fault
406C 00B0 Bus controller failure
406C 00B1 Bus controller failure
406C 00B3 Processor/VPD problem detected
406C 00B4 Processor/VPD problem detected
406C 00B7 Insufficient hardware resources were detected to
continue IPL of the system after processor
subsystem testing and initialization was
completed.
406C 00D1 Informational message
406C 0100 Memory extender 0 on processor card 1
406C 0101 Memory extender 2 on processor card 1
406C 0130 Memory extender 0 on processor card 2
406C 0131 Memory extender 2 on processor card 2
406C 0A03 Reboot message on VPD channel 3 processor
card 1. Reboot is necessary for run-time array
gard to take effect.
406C 0A04 Reboot message on VPD channel 4 processor
card 2. Reboot is necessary for run-time array
gard to take effect.
406C 0B00 Problem with internal RIO interface (I/O slot 0,
I/O port 0)
406C 0B01 Problem with internal RIO interface (I/O slot 0,
I/O port 1)
406C 0B02 Problem with internal RIO interface (I/O slot 0,
I/O port 2)
Action or
possible failing FRU
DIMM
Location code: U0.1-P1-C2-M4
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
1. Check for system firmware updates.
2. Processor card 1
Location code: U0.1-P1-C1
1. Check for system firmware updates.
2. Processor card 2
Location code: U0.1-P1-C2
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Informational message
Processor card,
Location code: U0.1-P1-C1
Processor card,
Location code: U0.1-P1-C1
Processor card,
Location code: U0.1-P1-C2
Processor card,
Location code: U0.1-P1-C2
Reboot the system in slow mode. Run
diagnostics, and then go to "MAP 0235: System
Array Self-Repair Problem Resolution" in the
RS/6000 Eserver pSeries Diagnostic
Information for Multiple Bus Systems.
Reboot the system in slow mode. Run
diagnostics, then go to "MAP 0235: System
Array Self-Repair Problem Resolution" in the
RS/6000 Eserver pSeries Diagnostic
Information for Multiple Bus Systems.
CEC backplane, U0.1-P1
CEC backplane, U0.1-P1
1. Check for system firmware updates.
2. Check the cabling between the CEC and the
I/O subsystems.
3. CEC backplane, U0.1-P1
4. Call service support.
Chapter 5. Error code to FRU index
185