v If you receive a failure message indicating a hardware error, the problem might be either the
adapter or the PCI-X slot. Isolate the problem by swapping an identical adapter into the slot and
retrying. If you determine that you have failing hardware, call your service representative.
Note: After isolating the problem, be sure to swap the adapters back to their original slots.

Verifying jumpers on PCI-X adapter options

The Ethernet adapters used in NAS Gateway 500 do not have any hardware jumpers or switches to set.
The fibre-channel HBAs do have jumpers. The jumpers have been installed into the correct positions at
the factory, but this should be verified before installation.
FC 6239, the single-port fibre-channel HBA has two physical jumpers which should be set as follows:
v Jumper JX1, pins 1 to 2 only
v Jumper JX2, pins 2 to 3 only
FC 6240, the dual-port fibre-channel adapter, has two pairs of jumper blocks, one pair for each port. These
four jumpers should be set as follows:
v Jumper P1_JX1, pins 1 to 2 only
v Jumper P1_JX2, pins 2 to 3 only
v Jumper P2_JX1, pins 1 to 2 only
v Jumper P2_JX2, pins 2 to 3 only
332
NAS Gateway 500 Service Guide