Table 16. Service processor error codes (continued)
Error code Description
406E 0CA5 Invalid system configuration
406E 0CA6 No usable memory left in the system. The
system must be rebooted.
406E 0CA9 Incorrect or incompatible DIMMs are installed.
406E 0CAA System memory exceeds the limit for this
system type and model.
406E 0EA0 MOPS service processor code error.
406E 0EA1 Operating system code on main processor
406E 0EA2 PRD code on service processor error.
406E 0EA4 The service processor detected a problem but
was unable to isolate the source.
406E 0EAF Service processor code and system type are
unknown.
406E 0EB0 JTAG problem
406E 0EB1 Attention line 0 stuck fault
406E 0EB2 Attention line 1 stuck fault
406E 0EB3 Attention line 2 stuck fault
406E 0EB4 Attention line 3 stuck fault
406E 0EB5 Attention line 4 stuck fault
406E 0EB6 Attention line 5 stuck fault
406E 0EB7 Attention line 6 stuck fault
406E 0EB8 Attention line 7 stuck fault
194
NAS Gateway 500 Service Guide
Action or
possible failing FRU
1. Check that the processor cards and DIMMs
are properly installed and configured.
2. If there are any FRUs listed in the service
processor error log entry, replace them one
at a time.
3. Go to "MAP 1540: Problem Isolation
Procedures" on page 69.
Go to "MAP 1240: Memory Problem Resolution"
on page 52.
Check that the DIMMs are properly configured
and are the right type for the system.
Remove the DIMMs until the memory does not
exceed the limit for this system type and model.
1. Check for system firmware updates.
2. Call service support.
1. Check for operating system code updates.
2. If there are other symptoms, go (one
symptom at a time) to the "Quick Entry MAP"
on page 40 and follow the instructions.
3. Call service support.
1. Check for system firmware updates.
2. Call service support.
Call service support.
1. Check for system firmware updates.
2. Call service support.
Go to "MAP 1541: JTAG Problem Isolation" on
page 71.
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.