Advertisement

Table 16. Service processor error codes (continued)
Error code Description
4065 0004 Processor fault
4065 000E Processor capacity card
4065 0010 DIMM fault
4065 0011 DIMM fault
4065 0012 DIMM fault
4065 0013 DIMM fault
4065 0014 DIMM fault
4065 0015 DIMM fault
4065 0016 DIMM fault
4065 0017 DIMM fault
4065 0018 DIMM fault
4065 0019 DIMM fault
4065 001A DIMM fault
4065 001B DIMM fault
4065 001C DIMM fault
4065 001D DIMM fault
4065 001E DIMM fault
4065 001F DIMM fault
4065 00B0 Bus controller failure
4065 00B1 Bus controller failure
158
NAS Gateway 500 Service Guide
Action or
possible failing FRU
1. Check JTAG cable connections.
2. Processor card
Location code: U0.1-P1-C2
Operator panel
Location code: U0.1-L1
DIMM
Location code: U0.1-P1-C1-M8
DIMM
Location code: U0.1-P1-C1-M6
DIMM
Location code: U0.1-P1-C1-M1
DIMM
Location code: U0.1-P1-C1-M3
DIMM
Location code: U0.1-P1-C1-M7
DIMM
Location code: U0.1-P1-C1-M5
DIMM
Location code: U0.1-P1-C1-M2
DIMM
Location code: U0.1-P1-C1-M4
DIMM
Location code: U0.1-P1-C2-M8
DIMM
Location code: U0.1-P1-C2-M6
DIMM
Location code: U0.1-P1-C2-M1
DIMM
Location code: U0.1-P1-C2-M3
DIMM
Location code: U0.1-P1-C2-M7
DIMM
Location code: U0.1-P1-C2-M5
DIMM
Location code: U0.1-P1-C2-M2
DIMM
Location code: U0.1-P1-C2-M4
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2

Advertisement