v LED Control Menu
This menu displays the state of the system attention LED. Use this menu to toggle the attention LED
between identify (blinking) and off. It is not available when the system is in standby. An example of this
menu follows:
LED Control
1. Set/Reset Identify LED state
2. Clear System Attention Indicator
98. Return to Previous Menu
Enter LED index
0 >
Option 1 is only available when the system is in the error state (the CEC is powered on and the service
processor menus are available). If Option 1 is selected, a list of location codes of the system unit
drawer is shown. The panel is similar to the following:
1. U0.2-P1
2. U0.3-P1
Enter number corresponding to the location code, or
press Return to continue, or 'x' to return to the menu
If one of the devices is selected using the index number, the present state of its LED is displayed, and
you are given the option to toggle it as shown in the following example panel. The final state of the LED
is then displayed whether or not its state was changed.
U0.2-P1 is currently in the off state
Select from the following (1=IDENTIFY ON, 2=IDENTIFY OFF)
0>2
Please wait
U0.2-P1 is currently in the OFF state
(Press Return to continue)
Option 2, Clear System Attention Indicator, clears the attention indicator on the operator panel.
The processor subsystem disturbance/LED is on the operator panel. The I/O drawer fault/identify LED is
located on the front of each I/O subsystem.
v MCM/L3 Interposer Plug Count Menu
This option is not available on this system.
Chapter 9. Using the service processor
273