Specifications

This section contains system specifications for the NAS Gateway 500.
Note: Refer to the 7014 Series Model T00 and T42 Rack Installation and Service Guide, for information
on cabling power from the rack to the I/O subsystem.
Table 7. Specifications for the NAS Gateway 500
Dimensions
Height
Width
Depth
Weight
Minimum configuration
Maximum configuration
Electrical
Power source loading (typical in kVA)
Power source loading (max. in kVA)
Voltage range (V AC)
Frequency (hertz)
Voltage range (V dc)
Thermal output (typical)
Thermal output (max.)
Power input requirements (typical)
Power input requirements (max.)
Power factor - U.S., World Trade, Japan
Inrush current²
Maximum altitude³,⁴
Temperature requirements³
Humidity requirements⁴
(Noncondensing)
Wet bulb
Noise emissions
1, 5, 6
L
WAd
<L
>
pA
m
Installation and air flow
1. Noise emission notes:
a. L
is the declared sound power emission level for a production series of machines.
WAd
b. L
is the mean value of the sound pressure emission levels at the operator position (if any) for a production series of
pAm
machines.
c. <L
>
is the mean value of the space-averaged sound pressure emission levels at the one-meter positions for a production
pA
m
series of machines.
d. N/A = Not Applicable (no operator position).
e. All measurements are made in accordance with ISO DIS 779 and reported in conformance with ISO DIS 7574/4.
2. Inrush currents occur only at initial application of power; no inrush occurs during normal power off-on cycle.
3. The upper limit of the dry bulb temperature must be derated 1°C per 137 m (450 ft) above 915 m (3000 ft).
4. The upper limit of the wet bulb temperature must be derated 1°C per 274 m (900 ft) above 305 m (1000 ft).
5. Levels are for a single system installed in a T00 or T42 32-EIA rack with the center of the unit approximately 1500 mm (59 in.) off
the floor.
6. Levels apply to the following hardware configuration: 2-way 1 gigahertz processor, 3 hard files, 2048 gigabytes of RAM,
redundant system (two 645-watt power supplies, 2 processor fans).
7. All measurements made in accordance with ISO 7779 and declared in conformance with ISO 9296.
178 mm (7.0 in., 4 EIA units)
482.6 mm (19.0 in.)
641.4 mm (25.25 in.)
34.92 kg (78.70 lbs)
39.03 kg (87.49 lbs)
2-way processor: 0.348, 4-way processor: 0.522
2-way processor: 0.522, 4-way processor: 0.783
100 to 127 or 200 to 240 (autoranging)
50 / 60
Not supported
2-way processor: 1129 Btu/hr, 4-way processor: 1693 Btu/hr
2-way processor: 1693 Btu/hr, 4-way processor: 2540 Btu/hr
2-way processor: 330 watts, 4-way processor: 500 watts
2-way processor: 500 watts, 4-way processor: 750 watts
0.96
50 amps
2135 m (7000 ft)
Operating
5 to 35°C (41 to 95°F)
Operating
8 to 80%
27°C (80°F)
Operating
6.1 bels
44 dBA
Maintenance of service clearance will allow proper air flow.