Table 16. Service processor error codes (continued)
Error code Description
4503 301E Description: 1 GB DIMM fault
Action: This error code indicates that the memory repeat gard function has deconfigured a quad of
memory. Do the following:
1. Go to the memory configuration/deconfiguration menu, located under the system information
menu in the service processor menus.
Look at the status of the DIMMs. If any of the DIMMs has a status of manually deconfigured,
reconfigure the DIMMs and boot the system to the SMS menus. Power off the system using the
white power button and look again at the status of the DIMMs.
If all of the DIMMs are configured in the memory configuration/deconfiguration menu, the
problem has been resolved.
If any of the DIMMs has a status of deconfigured by the system, either before or after the boot
to the SMS menus, go to step 2.
2. Replace the quad of memory containing the DIMM specified by the location code. The entire
quad of memory must be replaced.
4503 302E Description: 2 GB DIMM fault
Action: This error code indicates that the memory repeat gard function has deconfigured a quad of
memory. Do the following:
1. Go to the memory configuration/deconfiguration menu, located under the system information
menu in the service processor menus.
Look at the status of the DIMMs. If any of the DIMMs has a status of manually deconfigured,
reconfigure the DIMMs and boot the system to the SMS menus. Power off the system using the
white power button and look again at the status of the DIMMs.
If all of the DIMMs are configured in the memory configuration/deconfiguration menu, the
problem has been resolved.
If any of the DIMMs has a status of deconfigured by the system, either before or after the boot
to the SMS menus, go to step 2.
2. Replace the quad of memory containing the DIMM specified by the location code. The entire
quad of memory must be replaced.
4503 302F Description: 256 MB DIMM fault
Action: This error code indicates that the memory repeat gard function has deconfigured a quad of
memory. Do the following:
1. Go to the memory configuration/deconfiguration menu, located under the system information
menu in the service processor menus.
Look at the status of the DIMMs. If any of the DIMMs has a status of manually deconfigured,
reconfigure the DIMMs and boot the system to the SMS menus. Power off the system using the
white power button and look again at the status of the DIMMs.
If all of the DIMMs are configured in the memory configuration/deconfiguration menu, the
problem has been resolved.
If any of the DIMMs has a status of deconfigured by the system, either before or after the boot
to the SMS menus, go to step 2.
2. Replace the quad of memory containing the DIMM specified by the location code. The entire
quad of memory must be replaced.
Action or
possible failing FRU
Chapter 5. Error code to FRU index
203