SPCN error codes

Attention:
If a power supply or fan is hot-swapped, wait five minutes, and then recheck the operating
system error log. If the system has to be shut down to replace a power supply or fan, reboot the system,
wait five minutes after the operating system login prompt appears, and then recheck the operating system
error log. If the detailed information for the most recent error with the same identifier indicates that the
original problem has not been fixed by performing the first action in the action column, continue with the
next action in the action column.
Attention:
If you replace FRUs or perform an action and the problem is still not corrected, go to "MAP
1548: Processor Subsystem Problem Isolation" on page 77 unless otherwise indicated in the tables.
If you replace FRUs and the problem is corrected, go to "MAP 0410: Repair Checkout" on page 45.
Note: Not all SPCN error codes are supported.
Table 13. SPCN error codes for the CEC (system unit)
Error code Description
1011 00AC AC loss or brownout detected.
1011 00EF Room emergency power off detected.
1011 1510 Power supply 1 power source failure.
1011 1511 Power supply 1 fault
1011 1512 Power supply 1 non-power fault
1011 1513 Power supply 1 domain fault
1011 1520 Power supply 2 power source failure
Action or
possible failing FRU
Informational
Informational
1. Check input power to the power supply.
2. System power supply 1
Location code: U0.1-V1
3. CEC backplane
Location code: U0.1-P1
1. Verify that the media support shelf is
installed and properly seated.
2. System power supply 1
Location code: U0.1-V1
3. CEC backplane
Location code: U0.1-P1
1. System power supply 1
Location code: U0.1-V1
2. CEC backplane
Location code: U0.1-P1
1. Verify that the media support shelf is
installed and properly seated.
2. System power supply 1
Location code: U0.1-V1
3. CEC backplane
Location code: U0.1-P1
1. Check input power to power supply 2.
2. System power supply 2
Location code: U0.1-V2
3. CEC backplane
Location code: U0.1-P1
Chapter 5. Error code to FRU index
129