IBM TotalStorage NAS Gateway 500 Service Manual page 201

Hide thumbs Also See for TotalStorage NAS Gateway 500:
Table of Contents

Advertisement

Table 16. Service processor error codes (continued)
Error code Description
406B 0018 DIMM fault
406B 0019 DIMM fault
406B 001A DIMM fault
406B 001B DIMM fault
406B 001C DIMM fault
406B 001D DIMM fault
406B 001E DIMM fault
406B 001F DIMM fault
406B 00B0 Bus controller failure
406B 00B1 Bus controller failure
406B 00B3 MCM/VPD problem detected.
406B 00B4 MCM/VPD problem detected.
406B 00B7 Insufficient hardware resources were detected to
continue IPL of the system after processor
subsystem testing and initialization was
completed.
406B 00D1 Informational message
406B 0100 Memory extender 0 on processor card 1
406B 0101 Memory extender 2 on processor card 1
406B 0130 Memory extender 0 on processor card 2
406B 0131 Memory extender 2 on processor card 2
406B 0A03 Reboot message on VPD channel 3 processor
card 1. Reboot is necessary for run-time array
gard to take effect.
Action or
possible failing FRU
DIMM
Location code: U0.1-P1-C2-M8
DIMM
Location code: U0.1-P1-C2-M6
DIMM
Location code: U0.1-P1-C2-M1
DIMM
Location code: U0.1-P1-C2-M3
DIMM
Location code: U0.1-P1-C2-M7
DIMM
Location code: U0.1-P1-C2-M5
DIMM
Location code: U0.1-P1-C2-M2
DIMM
Location code: U0.1-P1-C2-M4
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
1. Check for system firmware updates.
2. PCI riser card
Location code: U0.1-P2
1. Check for system firmware updates.
2. Processor card 1
Location code: U0.1-P1-C1
1. Check for system firmware updates.
2. Processor card 2
Location code: U0.1-P1-C2
Go to "MAP 1540: Problem Isolation Procedures"
on page 69.
Informational message
Processor card,
Location code: U0.1-P1-C1
Processor card,
Location code: U0.1-P1-C1
Processor card,
Location code: U0.1-P1-C2
Processor card,
Location code: U0.1-P1-C2
Reboot the system in slow mode. Run
diagnostics, and then go to "MAP 0235: System
Array Self-Repair Problem Resolution" in the
RS/6000 Eserver pSeries Diagnostic
Information for Multiple Bus Systems.
Chapter 5. Error code to FRU index
181

Advertisement

Table of Contents
loading

Table of Contents