Table 16. Service processor error codes (continued)
Error code Description
4503 30AA Description: 2 GB DIMM fault
Action: This error code indicates that the memory repeat gard function has deconfigured a quad of
memory. Do the following:
1. Go to the memory configuration/deconfiguration menu, located under the system information
menu in the service processor menus.
Look at the status of the DIMMs. If any of the DIMMs has a status of manually deconfigured,
reconfigure the DIMMs and boot the system to the SMS menus. Power off the system using the
white power button and look again at the status of the DIMMs.
If all of the DIMMs are configured in the memory configuration/deconfiguration menu, the
problem has been resolved.
If any of the DIMMs has a status of deconfigured by the system, either before or after the boot
to the SMS menus, go to step 2.
2. Replace the quad of memory containing the DIMM specified by the location code. The entire
quad of memory must be replaced.
4504 26F6 1-way processor card fault
4504 26F7 2-way processor card fault
4504 26F8 1-way processor card fault
4504 26FA 2-way processor card fault
4504 26FB 2-way processor card fault
4504 26FD 1-way processor card fault
4504 26FE 2-way processor card fault
4504 26FF 1-way processor card fault
4504 301A 128 MB DIMM fault
4504 301B 1 GB DIMM fault
4504 301C 256 MB DIMM fault
4504 301D 512 MB DIMM fault
4504 301E 1 GB DIMM fault
4504 302E 2 GB DIMM fault
4504 302F 256 MB DIMM fault
4504 303B 1 GB DIMM fault
Action or
possible failing FRU
Replace the processor card specified by the
location code.
Replace the processor card specified by the
location code.
Replace the processor card specified by the
location code.
Replace the processor card specified by the
location code.
Replace the processor card specified by the
location code.
Replace the processor card specified by the
location code.
Replace the processor card specified by the
location code.
Replace the processor card specified by the
location code.
Go to "MAP 1240: Memory Problem Resolution"
on page 52.
Go to "MAP 1240: Memory Problem Resolution"
on page 52.
Go to "MAP 1240: Memory Problem Resolution"
on page 52.
Go to "MAP 1240: Memory Problem Resolution"
on page 52.
Go to "MAP 1240: Memory Problem Resolution"
on page 52.
Go to "MAP 1240: Memory Problem Resolution"
on page 52.
Go to "MAP 1240: Memory Problem Resolution"
on page 52.
Go to "MAP 1240: Memory Problem Resolution"
on page 52.
Chapter 5. Error code to FRU index
207