1.6.4 SET CONT. LEVEL
This setting adjusts the normal and halftone scanning contrast (slice level) to one of five levels.
Use the [ ↑ ] or [ ↓ ] key to select the "04.SET CONT. LEVEL", and then press the
(1)
[ENTER] key.
SET CONT. LEVEL
1.NORMAL MODE
2.GRAY MODE
NORMAL MODE
Adjusts the slice level for normal scanning.
GRAY MODE
Adjust the slice level for halftone scanning.
Use [ ↑ ] or [ ↓ ] key to select the desired mode, and then press the [ENTER] key.
(2)
(3)
Enter the desired contrast level, using the [1] to [5] keys on the dial keypad, and then
press the [ENTER] key.
SET CONT. LEVEL
NORMAL MODE
CONTRAST LEVEL=(1-5)
(4)
After the display shows the screen below, it returns to the standby mode screen.
COMPLETED
March 2000 © TOSHIBA TEC
[MENU], [9], [5], [04]
← or "GRAY MODE"
← 1 (Light) to 5 (Dark)