Toshiba DP120F Service Manual page 631

Plain paper facsimile
Hide thumbs Also See for DP120F:
Table of Contents

Advertisement

1.5.3 MODEM TEST (Factory Test)
This test is used to check the MODEM signal outputs at different transmission speeds and
different frequencies. By measuring the difference in signal strength at different frequencies, it is
possible to plot the phone line's bandpass.
This test is performed at the factory for inspection and not required in the field.
Use the [ ↑ ] or [ ↓ ] key to select "03. MODEM TEST", and then press the [ENTER] key.
(1)
MODEM TEST
1.LINE-1
2.LINE-2
<Remarks>
(2)
Select "1. LINE-1" to test the LINE-1 side, and "2. LINE-2" to test the LINE-2 side, then
press the [ENTER] key.
MODEM TEST
2100Hz
(3)
Select the frequency by pressing the [START] key.
<Remarks>
(4)
When you complete the test, press the [STOP] key to return to the standby mode screen.
(5)
Depending on the result of the test, replace the Main PBA or the MODEM PBA, referring
to "Chapter 8 Removal/Replacement/Adjustment" on page 8-46 or 8-42.
March 2000 © TOSHIBA TEC
"2. LINE-2" is displayed only when LINE-2 is installed.
LINE-1
The frequencies are displayed as in the following order.
2100Hz → G3(V34) → G3(V17) → G3(V29) → G3(V27) → 2400BPS →
300BPS → 1850Hz → 1650Hz → 1100Hz → 1300Hz → ANSam → CM
→ CI → Repeats
[MENU], [9], [4], [03]
11-19
DP120F/DP125F Troubleshooting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp125f

Table of Contents