• FUNC 28
Bit
7
Transmission attenuator value for V.34 modem (Line 1):
6
Counted up in the range from 0000 to 1111, in units of -1 dB.
5
0000 to 1111 ... counts up for every -1db.
4
0000: 0 db
0001: -1 db
0010: -2 db
.
1001: -9 db.
.
1111: -15 db
3
Transmission attenuator value for V.34 modem (Line 2):
2
Counted up in the range from 0000 to 1111, in units of -1 dB.
1
0000 to 1111 ... counts up for every -1db.
0
0000: 0 db
0001: -1 db
0010: -2 db
.
1001: -9 db.
.
1111: -15 db
<Remarks>
FUNC 28 Bits 7 to 4 and Bits 3 to 0:
The bit settings allow the user to program the modem transmission attenuation level.
The smaller the set value, the higher the transmission level becomes. If errors occur
frequently or training is not sent, the transmission level should be changed, as a rule.
Default table
US TYPE
BIT US TW SG HK DE GB
7
1
1
1
6
0
0
0
5
0
0
0
4
1
1
1
3
1
1
1
2
0
0
0
1
0
0
0
0
1
1
1
March 2000 © TOSHIBA TEC
Contents
IT
BE NL
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
EUR TYPE
FI
ES AT CH SE DK NO PT FR
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
4-103
Link with User
Function Setting
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
DP120F/DP125F Function Settings
AU
1
1
0
1
1
1
0
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dp125f

Table of Contents