2.5 Sensor Block
2.5.1 Scanner Cover Open Switch
Before disassembling or reassembling, be sure to refer to "1. Before Disassembling or Reas-
sembling."
(1)
Remove the CIS cover. (Refer to "2.1.3 CIS Cover.")
(2)
Release the two hooks of the scanner cover open switch, and remove the scanner cover
open switch.
(3)
Disconnect the connector from the scanner cover open switch.
Scanner cover open switch
Connector
(4)
Reassemble the components in the reverse order of disassembly.
NOTE: After reassembling, perform the sensor test referring to the "Chapter 11:
1.5.4 SENSOR TEST" on page 11-20.
DP120F/DP125F Removal/Replacement
Fig. 8-2-127
8-100
Hook
08-02-127
March 2000 © TOSHIBA TEC