2.3.12 Sensor PBA
Before disassembling or reassembling, be sure to refer to "1. Before Disassembling or Reas-
sembling."
(1)
Open the scanner cover, and release the scanner cover stopper from the top cover.
Scanner cover
(2)
Remove the four screws from the scanner cover, and remove the scanner cover.
(3)
Disconnect the connector from CN1 on the sensor PBA.
Sensor PBA
CN1
March 2000 © TOSHIBA TEC
Fig. 8-2-70
Scanner cover
Connector
Fig. 8-2-71
Scanner cover stopper
Top cover
8-55
DP120F/DP125F Removal/Replacement
08-02-70
08-02-71