4. Lubrication
4.1 Mechanisms and Parts not to be Lubricated
• Drum
• ADF pad assembly
• White plate
• CIS
• LSU (especially laser beam slit)
• All PBA
• Fuser
• Transfer unit
• Rubber rollers
• Cover and plastic part
NOTE:
Avoid lubricating the areas around the above mechanism and parts. Should
they be lubricated or if oil runs down into them, thoroughly remove oil with
clean rags.
4.2 Notes on Lubrication
Before lubrication, thoroughly remove old oil, rust-preventing oil, dust and dirt with rags. Then,
apply a proper amount of oil. Oil should be applied to only the specified points.
4.3 Oil types and Makers
Lubricant Type
1
2
3
4
DP120F/DP125F Removal/Replacement
Specified oil
Floil GE-676
Multipurpose No. 00
Slicon Grease G-501
Floil GE-334C
8-136
Maker
Kanto Chemicals Co., Ltd.
ICI Co., Ltd.
Shinetsu Chemicals Co., Ltd.
Kanto Chemicals Co., Ltd.
March 2000 © TOSHIBA TEC