M When The Value; Increases By "1", The; When The Value - Toshiba e-STUDIO350 Service Handbook

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO350:
Table of Contents

Advertisement

Classifi-
Code
cation
410
Laser
Adjustment of primary
scanning laser writing start
position.
411
421
Drive
Adjustment of secondary
scanning direction repro-
duction ratio (fine adjust-
422
ment of main motor speed)
424
Drive
Fine adjustment of exit
motor speed
425
430
Image
Top margin adjustment
(blank area at the leading
edge of the paper)
431
Image
Left margin adjustment
(blank area at the left of the
paper along the paper
feeding direction)
432
Image
Right margin adjustment
(blank area at the right of
the paper along the paper
feeding direction)
433
Image
Bottom margin adjustment
(blank area at the trailing
edge of the paper)
434-0
Image
Bottom margin adjustment
(blank area at the trailing
edge of the paper)/
Reverse side at duplexing
434-1
Image
Right margin adjustment
(blank area at the right of
the paper along the paper
feeding direction)/Reverse
side at duplexing
435
Image
Top margin adjustment
(blank area at the leading
edge of the paper)
436
Image
Left margin adjustment
(blank area at the left of the
paper along the paper
feeding direction)
437
Image
Right margin adjustment
(blank area at the right of
the paper along the paper
feeding direction)
438
Image
Bottom margin adjustment
(blank area at the trailing
edge of the paper)
e-STUDIO350/352/353/450/452/453
ERROR CODE AND SELF-DIAGNOSTIC MODE
Adjustment mode (05) <e-STUDIO352/353/452/453>
Func-
Items
tion
PPC
PRT
PPC/
PRT
FAX
PPC/
PRT
FAX
PPC
PPC
PPC
PPC
PPC/
PRT
PPC/
PRT
PRT
PRT
PRT
PRT
2 - 68
07/11
Default
<Accept-
RAM
Contents
able
value>
128
M

When the value

<0-255>

increases by "1", the

writing start position
128
M
shifts to the front side
<0-255>
by approx. 0.0423mm.
138
M
When the value
<0-255>
increases by "1", the
reproduction ratio of
139
M
secondary scanning
<0-255>
direction increases by
approx. 0.04%.
107
M
When the value
<0-255>
increases by "1", the
rotation becomes faster
121
M
by approx. 0.05%.
<0-255>
0
M
When the value
<0-255>
increases by "1", the
blank area becomes
wider by approx.
0
M
0.0423mm.
<0-255>
0
M
When the value
<0-255>
increases by "1", the
blank area becomes
wider by approx.
0.0423 mm.
0
M
<0-255>
EUR: 48
M
UC:24
JPN: 24
Others:
48
<0-255>
12
M
<0-255>
24
M
<0-255>
0
M
<0-255>
0
M
<0-255>
0
M
<0-255>
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Pro-
cedur
e
1
1
1
1
1
1
1
4
4
1
1
1
1