[E] Image position adjustment of the secondary scanning direction
While pressing [0] and [5] simultaneously, turn the power ON → (Adjustment Mode)
(1)
(2)
Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3)
Press [FAX] to make a copy at the mode of A3 (LD), 400% and lower drawer.
(4)
Measure the distance D from the leading edge of the paper to 10 mm of the copied image of the
ruler.
(5)
Check if the distance D is within the range of 34±0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps 3. to 5. above.
<Procedure>
(Adjustment Mode) → (Key in the code [305] with the digital keys) → [START]
→ (Key in a value (acceptable values: 0 to 255))
→ Press the [ENTER] or the [INTERRUPT] button (stored in memory).
→ ("100% A" is displayed.)
* The larger the adjustment value, the more the image is shifted to the trailing edge (0.68 mm/
step).
Feeding direction
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Copied image of the ruler
10
20
D
Fig. 3-9
3 - 17
04/05
30
40
e-STUDIO350/352/353/450/452/453