When The Value - Toshiba e-STUDIO350 Service Handbook

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO350:
Table of Contents

Advertisement

Classifi-
Code
cation
593
Image
Gamma data
slope adjust-
ment
594
Image
595
Image
620
Image
Sharpness
adjustment
621
622
653
Image
Adjustment of
smudged/faint
text
654
Image
Adjustment of
smudged/faint
text
655
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Adjustment mode (05) <e-STUDIO350/450>
Func-
<Accept-
Items
tion
Text/Photo
PPC
Photo
PPC
Text
PPC
Text/Photo
PPC
Photo
PPC
Text
PPC
EUR: 45
Text/Photo
PPC
PS
PRT
PCL
PRT
2 - 57
Default
RAM
Contents
able
value>
0
SYS
One's place:
<0-99>
0:Equivalent to the set
value 5
0
SYS
1 to 9: Select the slope
<0-99>
of Gamma curve
0
SYS
(The larger the
<0-99>
value is, the larger
the slope
becomes.)
Ten's place:
0: Equivalent to the set
value 5
1 to 9: Select the slope
of low density (The
smaller the value is,
the darker the back-
ground becomes.)
00: Use default value
1
SYS

When the value

<0-99>
increases, the image
becomes sharper.
When the value
decreases, the image
2
SYS
becomes softer. The
<0-99>
smaller the value is, the
less the moire
becomes.One's place:
SYS
Fixed value (05-620 is
UC: 45
"1", 05-621 is "2", 05-
JPN: 45
622 is "5") Ten's place:
<0-99>
Sharpness intensity (0:
Use default value, 1-9:
Filter intensity)
208
SYS
Adjusts the level of the
<0-255>
smudged/faint
text.With increasing the
value, the faint text is
suppressed, and with
decreasing it, the
smudged text is sup-
pressed.
5
SYS
Adjustment of the
<0-9>
smudged/faint
text.With decreasing
5
SYS
the value, the faint text
<0-9>
is suppressed, and with
increasing it, the
smudged text is sup-
pressed.
e-STUDIO350/352/353/450/452/453
ERROR CODE AND SELF-DIAGNOSTIC MODE
Pro-
cedur
e
1
1
2
1
1
1
1
1
1
1