2.1.4

Printer function error

Following codes are displayed at the end of the user name on the print job log screen
(When GM-1010/3010, GM-2010, GM-1060/4060, GM-2060, GM-1061/4060, GM-2061, GM-1120/
4120, or GM-2120 is installed)
Error code
4030
No Printer Kit / Printer Kit function disabled: The Printer Kit (GM-1010) or the
Printer/Scanner Kit (GM-2010) is not installed. Or network printing of an XPS
file is performed without the Expansion Memory (GC-1230), or network print-
ing is performed after the termination of a trial period.
4031
HDD full during print: Large quantity image data by private print or invalid
network print are saved in HDD.
4032
Private-print-only error: Jobs other than Private print jobs cannot be per-
formed.
4033
Printing data storing limitation error: Printing with its data being stored to the
HDD temporarily (Proof print, Private print, Scheduled print, etc.) cannot be
performed.
4034
e-Filing storing limitation error: Printing with its data being stored to the HDD
(print and e-Filing, print to e-Filing, etc.) cannot be performed.
4035
Local file storing limitation error: Network FAX or Internet FAX cannot be sent
when "Local" is selected for the destination of the file to save.
4036
User authentication error: The user who intended to print a document is not
registered as a user.
A221
Print job cancellation: Print job (copy, list print, network print) is deleted from
the print job screen.
A222
Print job power failure: The power of the equipment is turned OFF during
print job (copy, list print, network print).
A290
Limit over error: The numbers of output pages have exceeded those speci-
fied with both of the department code and the user code at the same time.
A291
Limit over error: The number of output pages has exceeded the one speci-
fied with the user code.
A292
Limit over error: The number of output pages has exceeded the one speci-
fied with the department code.
e-STUDIO350/352/353/450/452/453
ERROR CODE AND SELF-DIAGNOSTIC MODE
Contents
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
2 - 22
07/11
Troubleshooting
P. 5-107
P. 5-107
P. 5-107
P. 5-107
P. 5-107
P. 5-107
P. 5-107
P. 5-108
P. 5-108
P. 5-108
P. 5-108
P. 5-108

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents