3.13 Adjustment of the Finisher (MJ-1023/1024)

Note:
Note:
Before performing each adjustment, make sure that all covers (incl. those of the finisher and host
machine) are closed. Otherwise, the power is not supplied to the finisher and the adjustment may
not be performed properly.
3.13.1

Adjusting the alignment position (Finisher unit)

Perform this adjustment after replacing the finisher controller PC board or when the alignment position
must be changed for some reason.
(1)
Remove the rear cover of the finisher unit.
(2)
Check that the power is OFF and set SW104 on the finisher controller PC board as follows
according to the paper used for adjustment.
ON
1
2
(3)
Turn ON the power.
(4)
Press SW103 on the finisher controller PC board.
When SW103 is pressed, the swing guide opens and the alignment plate moves to prescribed
position.
(5)
Place ten sheets of A4/LT paper between the alignment plates and push them against the stop-
per.
(6)
Press SW101 or SW102 on the finisher controller PC board and push the alignment plate against
the paper.
When SW101 is pressed, alignment plate moves 0.42 mm forward.
When SW102 is pressed, alignment plate moves 0.42 mm backward.
(7)
When adjustment is complete, remove paper and press SW103 on the finisher controller PC
board once to store the adjustment in memory.
(8)
Turn OFF all bits of finisher controller PC board SW104.
(9)
Turn OFF the power and install the rear cover of the finisher unit.
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
3
4
5
6
7
8
A4 paper
Fig. 3-132
3 - 93
06/09
ON
1
2
3
4
5
6
7
LT paper
e-STUDIO350/352/353/450/452/453
8
ADJUSTMENT
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents