Procedure 14
[0][8]
[Digital key]
[POWER]
(Code)
Notes:
1. The digit after the hyphen in "Code" of the following table is a sub code.
2. e-STUDIO350/450:
In "RAM", the NVRAM of the board in which the data of each code is stored is indicated.
"M" stands for the LGC board, "SYS" and "UTY" stands for the SYS board and "NIC"
stands for the NIC board.
Classifi-
Code
cation
200
General
Date and time setting
201
General
Destination selection
202
User
Counter installed externally
interface
203
General
Line adjustment mode
204
User
Auto-clear timer setting
interface
e-STUDIO350/352/353/450/452/453
ERROR CODE AND SELF-DIAGNOSTIC MODE
[CANCEL]
[Digital key]
[START]
(Sub-code)
[CLEAR]
(Corrects value)
Setting mode (08) <e-STUDIO350/450>
Func-
Items
tion
ALL
ALL
ALL
ALL
ALL
2 - 84
07/05
[ENTER]
[START]
or
[INTERRUPT]
Adjustment value
cannot be changed
Default
<Accept-
RAM
able
value>
-
-
Year/month/date/day/
<13 dig-
hour/minute/second
its>
Example:
03 07 0 13 13 27 48
"Day" - "0" is for "Sun-
day". Proceeds Monday
through Saturday from
"1" to "6".
EUR: 0
M
0: EUR
UC: 1
1: UC
JPN: 2
2: JPN
<0-2>
0
M
0: No external counter
<0-3>
1: Coin controller
2: Copy key card
(This value is valid
only when "2" is set
to 08-201.)
3: Key copy counter
0
M
0: For factory ship-
<0-1>
ment
1: For line
*
Field: "0" must be
selected
3
SYS
Timer to return the
<0-10>
equipment to the
default settings when
the [START] button is
not pressed after the
function and the mode
are set
0: Not cleared
1 to 10:
Set number x 15
sec.
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved