Toshiba e-STUDIO350 Service Handbook page 549

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO350:
Table of Contents

Advertisement

5) Blurred image
Defective area
Step
Paper
1
Bedewed scanner
2
Drum
3
Ozone exhaust
4
5
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Check items
Is the paper in the drawer or LCF
damp?
Is the scanner bedewed?
Is the drum surface wet or dirty?
Is the ozone exhaust fan operating
properly?
Is the ozone filter stained or dam-
aged?
5 - 113
04/09
Prescription
Change paper. Avoid storing paper in
damp place.
Clean it.
Wipe the drum with a piece of dry cloth.
*
Do not use alcohol or other organic sol-
vents.
Check the connection of connector.
Replace the ozone exhaust fan.
Replace it.