15.3.1

Setting code

Each signal will be enabled by configuring the setting code "08-202" (Counter installed externally).
08-202
0: No external counter (Default)
1: Coin controller
2: Copy key card
3: Key copy counter
15.3.2
Setting value change and restrictions when using the totalizer
(DocuLyzerNW)
1. Setting value
-
08-202 (Counter installed externally): Set to "2" (Copy key card).
-
08-381 (Setting for counter installed externally): It should be charged precisely according to the
usage.
Example: To charge only when copies are made, set to "0".
2. Restrictions
-
08-352 (Large size double count setting): Set to "0" (Single count).
15.3.3
Setting value change and restrictions when using the coin
controller
1. Setting value
-
08-202 (Counter installed externally): Set to "1" (Coin controller).
-
08-381 (Setting for counter installed externally): It should be charged precisely according to the
usage.
Example: To charge only when copies are made, set to "0".
2. Restrictions
For 08-353 (Large size double count setting), set to "0" when A3 and LD are specified as the large
size, and set to "1" when B4, LG, FOLIO, COMP and 8K are specified as the large size in addition to
A3 and LD.
15.3.4

Simultaneous Installation of External Counters

It is not allowed to install more than one external counter at the same time. Physically, the multiple
external counters cannot be installed together since the output signals are used in common.
© 2009 TOSHIBA TEC CORPORATION All rights reserved