[ED14] Rear alignment plate home position error
MJ-1101
Is there any mechanical problem when the rear alignment plate is moved?
YES
Fix the mechanism.
NO
Is there a disconnection of the connector, incorrect installation or breakage of the rear align-
ment plate home position sensor (S8)?
l
YES
l
NO
Is the harness between the rear alignment plate home position sensor (S8) and the finisher
control PC board (CN11) disconnected or open circuited?
l
YES
NO
Is the harness between the rear alignment motor (M10) and the finisher control PC board
(CN10) disconnected or open circuited?
l
YES
NO
Replace the finisher control PC board.
[ED15] Paddle home position error
MJ-1101
Is there any mechanical problem when the paddle is rotated?
YES
Fix the mechanism.
NO
Is there a disconnection of the connector, incorrect installation or breakage of the paddle home
position sensor (S3)?
l
YES
l
NO
Is the harness between the paddle home position sensor (S3) and the finisher control PC
board (CN5) disconnected or open circuited?
l
YES
NO
Is the harness between the paddle motor (M8) and the finisher control PC board (CN6) discon-
nected or open circuited?
l
YES
NO
Replace the finisher control PC board.
e-STUDIO350/352/353/450/452/453
TROUBLESHOOTING
Connect the connector securely.
Reinstall the sensor correctly.
Replace the sensor.
Reconnect the connector securely.
Replace the harness.
Reconnect the connector securely.
Replace the harness.
Connect the connector securely.
Reinstall the sensor correctly.
Replace the sensor.
Reconnect the connector securely.
Replace the harness.
Reconnect the connector securely.
Replace the harness.