Advertisement

Classifi-
Code
cation
710
Mainte-
Short time interval setting
nance
of recovery from Emer-
gency Mode
711
Mainte-
Short time interval setting
nance
of Emergency Mode
715
Mainte-
Remote-controlled service
nance
periodical polling timing
(Hour/Hour/Minute/Minute)
716
Mainte-
Remote-controlled service
nance
Writing data of self-diag-
nostic code
717
Mainte-
Remote-controlled service
nance
response waiting time
(Timeout)
718
Mainte-
Remote-controlled service
nance
initial registration
719
Mainte-
Remote-controlled service
nance
tentative password
720
Mainte-
Status of remote-con-
nance
trolled service initial regis-
tration (Display only)
721
Mainte-
Service center call function
nance
723
Mainte-
Service center call HTTP
nance
server URL setting
726
Mainte-
HTTP proxy setting
nance
727
Mainte-
HTTP proxy IP address
nance
setting
728
Mainte-
HTTP proxy port number
nance
setting
729
Mainte-
HTTP proxy ID setting
nance
730
Mainte-
HTTP proxy password set-
nance
ting
731
Mainte-
HTTP proxy panel display
nance
732
Mainte-
Automatic ordering func-
nance
tion of supplies
(Remote)
733
Mainte-
Automatic ordering func-
nance
tion of supplies
(Remote)
FAX number
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08) <e-STUDIO352/353/452/453>
Func-
Items
tion
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
2 - 179
07/11
Default
<Accept-
RAM
Contents
able
value>
24
SYS
Sets the time interval to
<1-48>
recover from the Emer-
gency Mode to the Nor-
mal Mode.
(Unit: Hour)
60
SYS
Unit: Minute
<30-360>
1230
SYS
0 (0:00) to 2359 (23:59)
0
SYS
0: Prohibited
<0-1>
1: Accepted
3
SYS
Unit: Minute
<1-30>
0
SYS
0: OFF
<0-3>
1: Start
2: Only certification is
scanned
3: Sattelite communi-
cation starts
-
SYS
Maximum 10 letters
0
SYS
0: Not registered
<0-1>
1: Registered
2
SYS
0: OFF
<0-2>
1: Notifies all service
calls
2: Notifies all but
paper jams
-
SYS
Maximum 256 letters
1
SYS
0: Valid
<0-1>
1: Invalid
-
SYS
000.000.000.000 -
255.255.255.255
(Default value
000.000.000.000)
0
SYS
<0-
65535>
-
SYS
Maximum 30 letters
-
SYS
Maximum 30 letters
1
SYS
0: Valid
<0-1>
1: Invalid
3
SYS
0: Ordered by FAX
<0-3>
1: Ordered by E-mail
2: Ordered by HTTP
3: OFF
-
SYS
Maximum 32 digits
Enter hyphen with the
[Monitor/Pause] button
e-STUDIO350/352/353/450/452/453
ERROR CODE AND SELF-DIAGNOSTIC MODE
Pro-
cedur
e
1
2
1
1
1
1
1
11
2
1
11
1
11
1
11
11
1
1
11

Hide quick links: