Toshiba e-STUDIO350 Service Handbook page 301

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO350:
Table of Contents

Advertisement

(4)
Make an adjustment in the order of step 1
and 2.
Step 1
-
In case of A
Tighten the mirror-3 adjustment screw
(CW).
-
In case of B
Loosen the mirror-3 adjustment screw
(CCW).
Step 2
-
In case of C
Tighten the mirror-1 adjustment screw
(CW).
-
In case of D
Loosen the mirror-1 adjustment screw
(CCW).
(5)
Apply the screw locking agents to the adjust-
ment screws. (2 areas)
Recommended screw lock agent
Manufacturer: Three Bond
Product name: 1401E
© 2003 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Adjustment screw
for the mirror-1 (Rear)
Fig. 3-5
3 - 13
04/09
Carriage-1
e-STUDIO350/352/353/450/452/453